47 Elm Street, Wheelers Hill
Internal Architectural ChecklistReview run: 24 Sept 2026, 10:15am
- Builder/Designer:
- Sample Homes Pty Ltd
- Job No:
- 00000
- Drawing Set:
- Example Residence — Contract Documentation
- Class:
- Class 1a
- Revision:
- Rev C
- Date:
- 02/09/26
This is a contract-issue drawing set (Rev C, 02/09/26) for a two-storey Class 1a dwelling at 47 Elm Street, Wheelers Hill. The drawings are generally well-developed and include detailed internal elevations, construction details, overlooking and overshadowing diagrams. However, a number of significant issues are identified: site coverage in the site analysis table (64.2%) exceeds the 60% maximum under Clause 54 (ResCode) and requires urgent attention. Several supporting documents are absent from the provided set, including a copy of title, plan of subdivision, soil report and energy rating certificate — these are essential for a complete internal quality review. Several checklist items across the floor plans, roof plan and elevations sections require attention before the set can be considered construction-ready.
Key Metrics
- Total Site Area
- 612.40 sqm (site plan)
- Dwelling Area
- 301.6 sqm total (GF 176.2 sqm, FF 125.4 sqm)
- Site Coverage
- 64.2% (site analysis table)
- Hard Surface Coverage
- 14.1% (site analysis table)
- Permeability
- 21.7%
- Overall Height
- RL 58.320 (ridge) — approx. 7.6 m above NGL
- Wall Height
- Max shown on elevations — boundary wall 3.2 m
- Front Setback
- Approx. 7.5 m (setout dimension on site plan)
- Side Setback
- North ~1.1 m; South ~1.8 m
- Rear Setback
- Approx. 6.2 m (scaled from site plan)
- Avg Neighbouring Setback
- Not explicitly stated
Documents Provided
- Architectural Drawingsprovided
- Copy of Titlemissing
- Plan of Subdivisionmissing
- Surveyprovided
- Soil Reportmissing
- Planning Overlays & Zones informationprovided
- Energy Rating Reportmissing
- Electrical plansmissing
- Arborist reportmissing
- Dial Before You Dig documentsmissing
- Fixtures & Fittings schedulemissing
- Colours & material schedulemissing
Priority Actions
- SITE COVERAGE: The site analysis table (A03) shows site coverage of 64.2%, which exceeds the standard 60% maximum under Clause 54.03-3 (ResCode, Standard A5). Review and reduce site coverage or obtain planning assessment.
- ENERGY RATING: No energy rating report or stamped plans are included in the set. Confirm the applicable NCC version — if NCC 2022 applies, a minimum 7-star NatHERS rating is required. Obtain the energy report before issue.
- SIDE SETBACK: North side setback scales at approx. 1.1 m to the upper-level wall. Confirm the wall height and check against the Clause 54.04-1 side and rear setback requirement (Standard A10).
- SUPPORTING DOCUMENTS: Copy of title, plan of subdivision and soil report are not included. These are required to confirm easements, lot dimensions and footing design.
Detailed Review
- Documents Provided9 issues12 items
- Planning & Site Controls1 issue10 items
- Rescode — Part 4 (Clause 54/55)2 issues15 items
- Title Block & Document Control1 issue15 items
- Site Plan3 issues53 items
- Slab Plan27 items
- Floor Plans2 issues77 items
- Roof Plan1 issue22 items
- Elevations2 issues47 items
+ 13 more sections, including Window Schedule, Internal Elevations, Stairs, Electrical Plans, Overlooking Plans, Overshadowing Plans and Construction Details.